PD (Peritoneal Dialysis) Solutions

WHAT IS EXTRANEAL?

EXTRANEAL (icodextrin) peritoneal dialysis solution is for use in the long (8- to 16-hour) dwell.  When compared to 4.25% dextrose, EXTRANEAL can improve long-dwell ultrafiltration and clearance of creatinine and urea nitrogen for patients with high-average or high peritoneal transport characteristics.

 

Long history of international use 

  • Clinical experience in more than 19,000 patients in more than 45 countries
  • Used in Europe for more than 10 years

 

For more information on EXTRANEAL (icodextrin), including access to the EXTRANEAL training program, click here:  

 

PRESCRIBING INFORMATION

EXTRANEAL (icodextrin) PD solution is indicated for a single daily exchange for the long (8- to 16-hour) dwell during continuous ambulatory peritoneal dialysis (CAPD) or automated peritoneal dialysis (APD) for the management of end-stage renal disease.

 

EXTRANEAL is also indicated to improve (compared to 4.25% dextrose) long-dwell ultrafiltration and clearance of creatinine and urea nitrogen in patients with high-average or greater transport characteristics, as defined using the peritoneal equilibration test (PET).

IMPORTANT SAFETY INFORMATION

EXTRANEAL (icodextrin) PD solution is contraindicated in patients with a known allergy to cornstarch or icodextrin or in patients with glycogen storage disease.

 

EXTRANEAL is not for intravenous injection.

 

Since falsely elevated glucose levels have been observed with blood glucose monitoring devices and test strips that use glucose dehydrogenase pyrroloquinolinequinone (GDH PQQ) or glucose-dye-oxidoreductase-based methods, these methods should not be used to measure glucose levels in patients administered EXTRANEAL. Falsely elevated glucose levels may mask true hypoglycemia or lead to the erroneous diagnosis of hyperglycemia and administration of more insulin than needed.  Both of these situations can result in loss of consciousness, coma, neurological damage and death. The manufacturer(s) of the monitor and test strips should be contacted to determine if icodextrin or maltose causes interference or falsely elevated glucose results.

 

Treatment should be initiated and monitored under the supervision of a physician knowledgeable in the management of patients with renal failure.

 

A patient's volume status should be carefully monitored to avoid hyper- or hypovolemia and potentially severe consequences including congestive heart failure, volume depletion and hypovolemic shock. An accurate fluid balance record must be kept and the patient's body weight monitored.

 

Patients with insulin-dependent diabetes may require modification of insulin dosage following initiation of treatment.

 

In clinical trials, the most frequently reported adverse events occurring in > 5% of patients, and more common in EXTRANEAL patients than in control patients, were peritonitis (26% vs 25%), upper respiratory infection (15% vs 13%), hypertension (13% vs 8%), and rash (10% vs 5%). The most common treatment-related adverse event for EXTRANEAL patients was skin rash (5.5% vs 1.7%).

 

Please see full prescribing information.

 